Ceiling/floor type split inverter heat pump
Cooling 5,3 (1,6-5,9) kW, el. 1,62 kW
Heating 5,3 (1,6-5,9) kW, el. 1,41 kW
Performance | |
Capacity Cooling, kW | 5,3 (1,6-5,9) |
Capacity Heating, kW | 5,3 (1,6-5,9) |
Power consumption Cooling, kW | 1,62 |
Power consumption Heating, kW | 1,41 |
Energy Efficiency Cooling (+35 °C) EER | 3,62 |
The Seasonal Energy Efficiency Ratio in cooling SEER | 6,2 |
Energy Efficiency Heating (+7 °C) COP | 3,74 |
The Seasonal Coefficient of Performance in heating SCOP | 3,8 |
Cooled area, m² | 53 |
Heated area, m² | 47-118 |
Air circulation, m³/h | 900/750/600 |
Low Ambient Cooling, °C | -15 ~ +50 |
Low Ambient Heating, °C | -15 ~ +24 |
General Feature | |
Noise Level Indoor, dB(A) | 46/43/40 |
Noise Level Outdoor, dB(A) | 60 |
Low temperature keeping function, min °C | |
Autorestart | + |
Timer | + |
Wireless remote Control | + |
Compressor | Inverter |
Refrigerant | R410a (1,800g) |
Additionally | Winter kit for cooling to -15°C. |
Dimensions and weight | |
Dimensions indoor WxHxD, mm | 1068x235x675 |
Dimensions outdoor WxHxD, mm | 845x700x320 |
Weight indoor, kg | 25 |
Weight outdoor, kg | 46 |
Мounting Info | |
Power Source, V/Hz/f | 230/50/1 |
Electrical connections | to indoor, to outdoor |
Power cable | 3x1,5, 3x2,5 |
Signal cable | 4x0,5 shielded |
Rated current Cooling, A | 7,05 |
Rated current Heating, A | 6,13 |
Maximum current, A | 10,0 |
Refrigerant pipe connections, ″ | 1/4 - 1/2 |
Max. piping distance horizontal, m | 30 |
Max. piping distance vertical, m | 20 |
Warranty | |
Warranty for devices, months | 24 |
Installation warranty, months | 24 |
AlpicAir AFI/AOU-53HPDC1A
- Brand: AlpicAir
- Product Code: AFI/AOU-53HPDC1A
- Availability: No longer provide
-
1 226.10€