Heating 11,38 kW el. 2,64 kW
Cooling 11,72 kW, el. 4,31 kW
Air to water heat pump Daikin Altherma 2 EHVX11S26CB9W/ERLQ011CW1, built-in 260 l water tank. Guaranteed heating operation down to -25°C.
Daikin Altherma low temperature split
Guaranteed operation: Daikin Altherma is suitable for all climates, even withstanding severe winter conditions
• Daikin is renowned for its know-how related to frost protection on its heat pump range. The outdoor units are specifically designed to avoid ice build-up problems, even in the most severe winter conditions.
• Daikin Altherma low temperature has a guaranteed operation down to an outside temperature of -25°C. This ensures sufficient heat pump operation for even the coldest climates.
The 11-16kW range of Daikin Altherma (ERLQ-C) has specific frost protection:
• Hot gas pass: hot gaseous refrigerant coming from the compressor runs through the bottom plate to keep the base free of ice and all the drain holes open..
• Sub-cool pass: before the refrigerant pipe is split by the distributor to the hairpins, the refrigerant passes through the bottom of the coil to keep this lower part free of ice.
• Our advanced protection against frost and icing means that we can offer the Daikin Altherma across the whole of Europe.
| Performance | |
| Heated area, m² | 115-200 |
| Backup heater, Capacity, kW×pcs | 9,0 |
| Low Ambient Heating, °C | -25...+35 |
| +7°C/+35°C floor heating, Heating capacity, kW | 11,38 |
| +7°C/+35°C floor heating, Input power, kW | 2,64 |
| +7°C/+35°C floor heating, COP | 4,31 |
| General Feature | |
| Heating. Leaving water temperature range, °C | +15...+55 |
| DHW. Leaving water temperature range, °C | +25...+60 |
| DHW capacity, L | 260 |
| Water circulation rated/min/max, L/min | 30/11/50 |
| Noise Level Outdoor, dB(A) | 51 |
| Refrigerant | R410A (3,40 kg, >10m + 54g/m) |
| Dimensions and weight | |
| Dimensions indoor WxHxD, mm | 600х1732х728 |
| Dimensions outdoor WxHxD, mm | 900х1345х320 |
| Weight indoor, kg | 129 |
| Weight outdoor, kg | 114 |
| Мounting Info | |
| Power Source, V/Hz/f | 400/50/3 + 400/50/3 |
| Electrical connections | to indoor unit, to outdoor unit |
| Current, Outdoor unit, Rated/Max, A | 6,0/16,3 |
| Current, hydraulic unit, Max, A | 13,0 |
| Water pipe connection diameter, Flow/Return, mm | G 1"1/4 (female) |
| Hot water pipe diameter, mm | G 1" (female) - G 1" (female) - G 1/2" (female) |
| Refrigerant pipe connections, ″ | 3/8-5/8 |
| Max. piping distance horizontal, m | Min/Max 3/50 |
| Max. piping distance vertical, m | 30 |
Daikin Altherma 2 EHVX11S26CB9W/ERLQ011CW1
- Brand: DAIKIN
- Product Code: Daikin Altherma 2 LT EHVX11S26CB9W/ERLQ011CW1
- Availability: No longer provide
-
7 995,52€
- Ex Tax: 6 448,00€
Available Options
Related Products
Daikin Altherma LAN Online controller via app BRP069A62
Daikin online controller BRP069A62 - Always in control Control your Daikin Altherma indoor unit from any location via app Set your holid..
147,00€ Ex Tax: 118,55€
Daikin Altherma LAN Online controller via app BRP069A61
Daikin online controller BRP069A61 - Always in control Control your Daikin Altherma indoor unit from any location via app App contr..
220,00€ Ex Tax: 177,42€
Tags: Daikin, Altherma, air to water heat pump, 260 l water tank, R410A, inverter