Heated area up to 220 m²
Built-in 230 l water tank
The Seasonal Coefficient of Performance in heating SCOP 4,15
Air to water heat pump Daikin Altherma 3 H HT ETVX16S23E9W7/EPRA14DW17, built-in 230 l water tank, next generation refrigerant R32.
All hydraulic components are included.
Guaranteed heating operation down to -28°C.
Owner's Manual Daikin Altherma 3 H HT | Catalogue "Air to water heat pump Daikin Altherma H HT" |
Daikin Altherma 3 H HT high temperature split
Wall mounted reversible air-to-water heat pump
• Inclusion of all hydraulic components means no third party components are required
• PCB board and hydraulic components are located in the front for easy access.
• Compact dimensions allows for small installation space, as almost no side clearances are required.
• The unit’s sleek design blends in with other household appliances.
• Combine with a stainless steel tank or ECH2O thermal store.
• Outdoor unit extracts heat from the outdoor air, even at -28°C
Integrated WiFi Online Controller
Control your indoor unit from any lcoation via smart phone, laptop, pc, tablet or touch screen.
Madoka wired remote control - sleek and elegant design, available in three colours (optional)
A complete redesigned controller focused to enhance user experience.
Performance | |
Backup heater, Capacity, kW×pcs | 3-6-9 |
Low Ambient Heating, °C | -28...+35 |
+7°C/+35°C floor heating, Heating capacity, kW | max 9,8 |
+7°C/+35°C floor heating, Input power, kW | max 2,17 |
+7°C/+35°C floor heating, COP | 4,52 |
-7°C/+35°C floor heating, Heating capacity, kW | max 10,7 |
-7°C/+35°C floor heating, Input power, kW | max 3,52 |
-7°C/+35°C floor heating, COP | 3,04 |
-15°C/+35°C floor heating, Heating capacity, kW | max 9,4 |
-15°C/+35°C floor heating, Input power, kW | max 3,84 |
-15°C/+35°C floor heating, COP | 2,45 |
-20°C/+35°C floor heating, Heating capacity, kW | max 8,1 |
-20°C/+35°C floor heating, Input power, kW | max 3,63 |
-20°C/+35°C floor heating, COP | 2,23 |
-25°C/+35°C floor heating, Heating capacity, kW | max 7,8 |
-25°C/+35°C floor heating, Input power, kW | max 3,8 |
-25°C/+35°C floor heating, COP | 2,05 |
-7°C/+45°C radiators, Heating capacity, kW | max 10,7 |
-7°C/+45°C radiators, Input power, kW | max 3,85 |
-7°C/+45°C radiators, COP | 2,78 |
-15°C/+45°C radiators, Heating capacity, kW | max 9,8 |
-15°C/+45°C radiators, Input power, kW | max 4,58 |
-15°C/+45°C radiators, COP | 2,14 |
-25°C/+45°C radiators, Heating capacity, kW | max 7,9 |
-25°C/+45°C radiators, Input power, kW | max 4,5 |
-25°C/+45°C radiators, COP | 1,76 |
General Feature | |
Heating. Leaving water temperature range, °C | +18...+70 |
DHW. Leaving water temperature range, °C | +25...+60 |
DHW capacity, L | 230 |
Noise Level Outdoor, dB(A) | 43 |
Refrigerant | R32 (4,2 kg) |
Dimensions and weight | |
Dimensions indoor WxHxD, mm | 595х1850х625 |
Dimensions outdoor WxHxD, mm | 1270х1003х533 |
Weight indoor, kg | 118 |
Weight outdoor, kg | 151 |
Мounting Info | |
Power Source, V/Hz/f | 400/50/3 |
Electrical connections | to indoor unit, to outdoor unit |
Water pipe connection diameter, Flow/Return, mm | G 1" (female) |
Max. piping distance horizontal, m | Max 50 |
Max. piping distance vertical, m | 10 |